Page 1: ...BOLLARD WITH RETRACTABLE OIL HYDRAULICALLY DRIVEN CYLINDER EN 13241 EN 12453 EN 12445 C730 GB Instructions manual pages 1 20 the gate opener ...

Page 2: ... crushing and impact force of the main opening and closing edge in compliance with EN 12445 Identify the appropriate solution necessary to eliminate and reduce such risks In case where the gate to automate is equipped with a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates ...

Page 3: ...s all the accessories are pre assembled and connected to the internal terminal board Beeper an acoustic device emitting an intermittent sound during the rising and lowering movements of the bollard Heater a device to keep warm the inside of TALOS C730 when the external temperature is lower than 5 C Colour customizing available in any RAL options polyester powder coating It comes along with the fol...

Page 4: ...t the junction box along with the connector NOTE WELL once testing is finished put back the box and the cover MAIN COMPONENTS Post cover with rubber edge and with N 12 warning LEDs flashing light amber colour Type approved retro reflecting sticker Hatch allowing connec tion of the electric cable from the electronic controller Cover plate Casing to embed in cement Ø 275 mm retractable cylinder 1 00...

Page 5: ...o the dedicated holes By means of a winch carefully hoist the inner assembly of the bollard and mind not to tear off or damage the oil pipes and the inner electrical cables M16 M16 M16 Casing to cement NOTE WELL before hoisting disconnect the ground cable from the casing M16 M8 M8 1 3 4 5 2 8 x M16 screws Remove the rectangular cover plate 5 anti terrorism oil hydraulic automatic bollard ...

Page 6: ...it either from a junction pit or directly from the Elpro S40 S20 electronic controller pic 5 NOTE WELL the foundation casing is to be set perfectly levelled and the upper edge must be 1 2 cm higher than pavement surface walking level Soakaway pebbles Inlet from below of the Ø 50 mm tube leading the electric cables Fit the two M16 lifting rings diagonally across the casing to allow proper hoisting ...

Page 7: ...ture class B450C ASTM A615 Grade 60 made of rebars whose yield point is 450 MPa and breaking point 540 MPa A1 n 1 pc n 26 pcs 1 200 mm ø 10 n 22 pcs 1 000 ø 10 ø 10 n 9 pcs ø 10 n 6 pcs 200 400 400 n 12 pcs ø 10 200 60 kg A2 A1 B B 275 330 400 n 12 pcs ø 10 300 1 200 mm ø 10 n 4 pcs 1 200 mm ...

Page 8: ...8 anti terrorism oil hydraulic automatic bollard C730 English 1 2 1 2 n 2 pcs B ø 10 n 6 pcs 300 400 3 4 Pic 8 A2 n 1 pc ø 10 n 6 pcs 200 400 ø 10 n 3 pcs 1 200 mm 70 70 ø 10 n 9 pcs 275 330 1 200 mm ...

Page 9: ...English 9 anti terrorism oil hydraulic automatic bollard C730 3 4 ø 10 n 1 pc 1 200 mm ø 10 n 4 pcs 1 000 mm ø 10 n 6 pcs 1 000 mm ø 10 n 2 pcs 1 000 mm 150150 A2 A1 B B Pic 9 Pic 11 Pic 10 ...

Page 10: ...ollard from staying flooded In case of snow the flat surface of the cover plate can be easily cleared even by heavy machanical means Pic 12 1 1 m 1 4 m The bollard must be positioned and perfectly levelled before concrete is poured all around the foundation cage Iron armature class B450C ASTM A615 Grade 60 made of rebars whose yield point is 450 MPa and breaking point 540 MPa Concrete specificatio...

Page 11: ...ate in compliance with the existing safety norms Connect it inside by the provided screw Pic 13 IP 66 The multicore cable BUT FLESSIBILE FG 7OR 12x1 5 mm see page 18 point 9 must not exceed 30 m of length Lay the ground cable in compliance with the installation requirements section as suitable Pic 14 INSTALLATION OF THE BOLLARD Once made sure that concrete has firmly set around the casing insert t...

Page 12: ...ED IP 66 Connections to the terminals of Elpro S40 S20 controller see the instructions included with this accessory Pic 16 NOTE WELL before carrying on with the electrical connections it is advisable to identify which optional accessories are mounted on TALOS C730 beeper or heating device and so be able to establish which connections are to be made to the connector Beeper inside the bollard Beeper...

Page 13: ...t switch normally ON off with the bollard in down position L9 M1 closing limit switch normally ON off with the bollard in standing position NOTE WELL the bollard is required to be fully down On installation phase should the bollard go up even partially proceed with the manual release and bring it fully down on to the bollard stop Pic 22 Close all NC contacts to Elpro S40 S20 controller Pic 18 Conn...

Page 14: ...RTANT BOLLARD AND COVER PLATE ARE TO BE PERFECTLY CENTERED SO THAT THE GAP BETWEEN BOLLARD AND COVER PLATE HOLE IS EQUALLY SPACED ALL AROUND The cover plate is to firmly rest all over the surface and closely adhere to the circular flange around the post M16 GREASE anti terrorism oil hydraulic automatic bollard C730 English C730 14 ...

Page 15: ...oltage It is possible though in particular situations of danger and or emergency to lower the bollard manually as follows Remove the fixing screws and take off the aluminium cover Insert the release spanner through the cover hole to fit it into the triangular profile of the lock and turn it one complete turn anti clockwise IMPORTANT once the bollard is fully down turn the spanner clockwise and tig...

Page 16: ...16 anti terrorism oil hydraulic automatic bollard C730 English ...

Page 17: ... Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by using Fadini original spare parts This document for the data included in it must be made available to authorized inspectors officers an...

Page 18: ...e proximity of the bollard 13 The manufacturer reserves the right to change this manual without previous notice As far as configuration and execution of the system are concerned these are to comply with the laws in the country of installation Meccanica Fadini is not liable for any possible damages derived from incorrect use or from any use not indicated in this manual furthermore it is not answera...

Page 19: ...anti terrorism oil hydraulic automatic bollard C730 19 English ...

Page 20: ... 400 475 575 Ø 275 1 000 1 510 mm anti terrorism oil hydraulic automatic bollard 2020 02 PRODUCT SPECIFICATIONS Fully retractable automatic bollard for very heavy duty applications made up of an incorporated oil hydraulic motor pump unit and an oil hydraulic actuator inside the moving cylinder Designed in compliance with ASTM PAS 68 K4 M30 C730 specifications vehicle of 7 5 t at a speed of 48 km h...