Multipole cable
and ground cable
Elpro S40/S20
ELECTRIC CONNECTIONS TO THE ELECTRONIC CONTROLLER ELPRO S40/S20
The electronic controller Elpro S40/S20 is to be installed in a dry and protected place to prevent unauthorized actions.
Make sure that all the electric cables of the command and safety accessories are properly led to the controller.
Through the previously laid corrugated tube pull a multicore cable, type
BUT FLESSIBILE FG 7OR 12x1,5 mm²
(not supplied
with the equipment, but available on request as per catalogue) for the electrical connections to the Elpro S40/S20 controller,
depending on which model of TALOS C730 is to be installed (see page 18, point 9).
NOTE WELL: lay a ground cable to suit the type of installation required, either public or private, in compliance with the
existing safety norms. Connect it inside by the provided screw.
Pic. 13
IP 66
The multicore cable BUT FLESSIBILE FG 7OR 12x1,5 mm² (see page 18, point 9) must not exceed
30 m of length.
Lay the ground cable in compliance with the installation requirements, section as suitable.
Pic. 14
INSTALLATION OF THE BOLLARD
Once made sure that concrete has firmly set around the casing, insert the inner assembly. Eventually remove the lifting rings.
By a winch hoist and insert the inner assembly
into the casing, minding not to tear, cut or
somehow damage the pipes and the internal
electric cables
They must be at
the same level
NOTE WELL: MAKE SURE THE ENTIRE INNER ASSEMBLY FITS
WELL INTO ITS SEAT. THE PLATE, ON WHICH THE
MOTOR-PUMP IS FIXED, MUST PROPERLY REST ON THE
CASING INNER SURFACE, CLEARED OF POSSIBLE CHIPS.
The parts must
perfectly fit into the
dedicated seat of the
ground casing
!
!
!
English
11
anti-terrorism oil-hydraulic automatic bollard