A watertight junction box is incorporated in the bollard with all the electrical connections to the bollard (electric motor, limit
switches, LED lights and beeper as an option). Remove the connector from the box and make the connections to the respective
terminals using a multicore cable (not provided with the equipment).
Pic. 15
Junction box with
connector
flasher and/
or beeper
PCB
“Heater for
Talos series”
(if mounted)
LED lights
motor
common
LEDs and/or beeper common
motor live
(Pic. 19)
[B]
motor live
(Pic. 19)
[B]
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
53
51
17
16
52
18
NOTE WELL: TIGHTEN THE CABLE GLAND
PROPERLY BEFORE FITTING BACK THE
CONNECTOR, OTHERWISE INFILTRACTION
PROTECTION GRADE CANNOT BE GUARANTEED.
IP 66
Connections to the terminals of Elpro S40/S20 controller
(see the instructions included with this accessory)
Pic. 16
NOTE WELL: before carrying on with the electrical connections, it is advisable to identify which optional
accessories are mounted on TALOS C730 (beeper or heating device), and so be able to establish which
connections are to be made to the connector.
Beeper
inside
the bollard
Beeper
Heater
Heating device
inside the
casing
!
!
!
12
11
56
ground limit switch
blue and gray cables - green wires
limit switch opening
gray cable - white wire
(Pic. 18)
[A]
limit switch closing
blue cable - white wire (Pic. 18)
[A]
55
limit 24 Vdc
blue and gray cables - brown wires
English
anti-terrorism oil-hydraulic automatic bollard
C730
C730
12
IP 66
NOTE WELL: a 40 μF capacitor is pre-wired inside the junction box.
An additional 20 μF capacitor is required to be connected to terminals A and B of Elpro S40/S20.