Chapter 4 - 38 Liter Bubbler Installation
_______________________________________________________________________________________________________________
MNL000625.doc
Revision 0
06/25/2019
Chemical Equipment
© Versum Materials US, LLC. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page 4
-
10
Versum Materials Confidential
2. Verify Coolant Drain Valve, MV55 is closed and end cap installed
3. Turn coolant water on
4. Verify with facilities that coolant water is circulating
5. Visually inspect all coolant water connections at CG cabinet and chiller connections at
outer coolant jacket of bubbler is leak free, no water leak observed
6. Once Bubbler installed and coolant water on and circulating enter Bubbler Net and
Current liquid weight.
4.12 Entering Bubbler Liquid Weight
From the Main Menu, enter Config Menu -> Net Product -> Bulk Scale.
Enter the following values;
Net Liquid:
43.4kg (100% chemical level of 38 Liter Bubbler)
Current Liquid Wgt: 00.0kg (Initial installation of the Bubbler, the current liquid weight
will be 0%
Figure 4-3: Bubbler Net Product Menu