Chapter 3 - Installation
_______________________________________________________________________________________________________________
MNL000624.doc
Revision 0
06/25/2019
Chemical Equipment
© Versum Materials US, LLC. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page 3
-
29
Versum Materials Confidential
3.10.2
User Setpoints
– PT1 and PT2
Configuring Bulk Push PT1 and PT2 “Pressure Alarm” setpoints
From the Main Menu, enter Config Menu -> User Setpoints -> PT1. Note, values shown are
recommended.
Table 3-15: User Setpoints > PT1
Num
Alarm Label
Setpoint
1
LOW PUSH PRESSURE
22
2
HI PUSH PRES PRESSURE
45
3
LOW PUSH PRESSURE
22
4
BULK VENT FAILED
22
5
PUMPDOWN CHECK
10
6
BASE VAC CHECK
5
7
GROSS LEAK PT1
22
8
PT1 HP VENT
28
From the Main Menu, enter Config Menu -> User Setpoints -> PT2. Note, values shown are
recommended.
Table 3-16: User Setpoints > PT2
Num
Alarm Label
Setpoint
1
LOW PUSH PRESSURE
22
2
HI PUSH PRES PRESSURE
45
3
PT1 HP VENT
28
4
HH PUSH PRESSURE
45