Specifications
Available
Functions
Stop transition buzzer
sound function
Buzzer sounds when the Stop switch is pressed during solution delivery.
LCD brightness select
function
Changes the LCD brightness.
Maintenance timer
function
Time to next maintenance check can be set. That information is displayed on
the LCD.
Date and time setting
function
Sets the date and time.
Free message function
Displays a message on the pump via communication.
External
communication
function (infrared
communication (IrDA))
Allows communication with the optional TERUFUSION Communication Rack
System to output the status of the pump (flow rate, alarms, etc.) via infrared.
External
communication
function (wireless LAN)
Allows communication with a network system to output the status of the pump
(flow rate, alarms, etc.) via wireless LAN.
History function
Displays the operation history, etc.
AC power detector
function
Detects the presence or absence of AC power supply to the pump and displays
that status.
AC power detector
buzzer sound function
Buzzer sounds when AC power supply is provided to or disconnected from the
pump.
Purge volume upper
limit setting function
Sets the upper limit of the purge volume.
Bolus volume upper
limit setting function
Sets the upper limit of the hands on bolus volume.
Keep Vein Open
Function
After activation of the Infusion Completion alarm, solution delivery is continued
at the keep vein open flow rate.
Keep Vein Open flow
rate select function
Changes the keep vein open flow rate.
During-start volume
delivered clear function
(except the TCI mode)
Clears the volume delivered to zero during solution delivery.
During-start flow rate/
dosage rate change
function
Changes the flow rate/dosage rate during solution delivery.
Selecting dose mode
during the solution
delivery function
Change the dose mode from mL/h to another mode during solution delivery.
Set value memory
function
Saves the current set values (e.g. flow rate, VTBI, dosage and weight) before
the power is turned off.
Alarm melody select
function
Changes the buzzing pattern (melody) of the alarm buzzer.
Setting dial
acceleration function
Rotating the Dial while pressing the Stop switch accelerates the setting rate to
set items such as the flow rate.
Hands On Bolus
function
After the bolus flow rate is set, a bolus is delivered while the Purge switch is
pressed.
Hands Free Bolus
function
When bolus volume and bolus time are set, the flow rate is calculated and a
bolus is delivered.
Shortcut call function
Press multiple keys in combination to directly call the bolus flow rate setting
display.
Night mode function
Changes the LCD brightness for a specified time period.