Remote Control
FPC1000
251
User Manual 1178.4130.02 ─ 02
Parameters:
<State>
OFF | 0
Turns off the measurement filter for unfiltered measurements.
ON | 1
Turns on the measurement filter selected with
*RST:
ON
Example:
//Perform unfiltered measurement
DDEM:FILT OFF
[SENSe:]DDEMod:SRATe
<SymbolRate>
This command defines the symbol rate.
Parameters:
<SymbolRate>
<numeric value> (integer only)
Default unit: Hz
Example:
//Define symbol rate
DDEM:SRAT 10KHZ
[SENSe:]DDEMod:TIME
<Symbols>
This command defines the number of symbols to be evaluated.
Parameters:
<Symbols>
<numeric value> (integer only)
Range:
20 to depends on measurement filter
*RST:
100
Example:
//Define the number of symbols
DDEM:TIME 150
13.13.3 Frequency
Commands to configure the frequency described elsewhere.
●
Center frequency:
●
Frequency stepsize:
●
Frequency offset:
Remote Commands of the Digital Demodulation