Remote Control
FPC1000
244
User Manual 1178.4130.02 ─ 02
Suffix:
<n>
.
irrelevant
Usage:
Event
CALCulate<n>:ADEModulation:LIMit:FAIL?
This command queries the results of the limit check.
Prerequisites for this command
●
Load a set of limit values (
CALCulate<n>:ADEModulation:LIMit:SELect
Suffix:
<n>
.
irrelevant
Return values:
<Result>
0
All numerical results are within the specified limits ("Pass"
result).
1
At least one of the numerical results violates the specified limit
("Fail" result).
Example:
//Query limit check results
CALC:ADEM:LIM:FAIL?
Usage:
Query only
CALCulate<n>:ADEModulation:LIMit:SELect
<Filename>
This command selects a set of limit values for AM and FM measurements.
Selecting a set of limit values automatically initiates a limit check of the numerical
results.
Suffix:
<n>
.
irrelevant
Parameters:
<Filename>
String containing the file name of the limits definition file.
The file extension is either
.amlim
(AM limits) or
.fmlim
(FM
limits).
Example:
//Load limit values for AM measurement
CALC:ADEM:LIM:SEL 'limits.amlim'