![Rohde & Schwarz 1430.0105K02 User Manual Download Page 55](http://html1.mh-extra.com/html/rohde-and-schwarz/1430-0105k02/1430-0105k02_user-manual_1477792055.webp)
Sensor Configuration
R&S
®
NRT2
55
User Manual 1178.5550.02 ─ 04
"IS95"
IS- 95 CDMA standard for base stations.
"WCDMA"
WCDMA standard for base stations.
"DVBT"
DVB-T standard for terrestrial DVB TV transmitters.
"DAB"
DAB standard for radio transmitters.
Remote command:
CALCulate<Measurement>[:CHANnel<Channel>]:NRT:DMODulation[:
VALue]
[SENSe<Sensor>:]DM:STATe
[SENSe<Sensor>:]DM:STANdard
WCDMA Chip Rate
Available if "WCDMA" is set under
Sets the chip rate for the WCDMA communication standard.
Remote command:
CALCulate<Measurement>[:CHANnel<Channel>]:NRT:DMODulation:WCDMa:
CRATe
6.3
Sensor Frequency
Access: "Measurement Overview" > "Channel Sensor Configuration" > "Frequency"
<Sensor name>
Sets the carrier frequency of the applied signal. This value is used for frequency-
response correction of the measurement result.
key opens the same dialog.
Sensor Frequency