![Rohde & Schwarz 1430.0105K02 User Manual Download Page 114](http://html1.mh-extra.com/html/rohde-and-schwarz/1430-0105k02/1430-0105k02_user-manual_1477792114.webp)
Remote Control
R&S
®
NRT2
114
User Manual 1178.5550.02 ─ 04
CALCulate<Measurement>:LIMit<DirectionalChannel>:LOWer[:DATA]:RATio:
SWR
<value>
Lower limit value for SWR.
Suffix:
<Measurement>
.
1...100
<DirectionalChannel> 1..2
Parameters:
<value>
Range:
0.0 to 1e18
*RST:
1.0
Default unit: -
Manual operation:
See
"Forward Lower Limit, Reflection Lower Limit"
CALCulate<Measurement>:LIMit<DirectionalChannel>:LOWer[:DATA]:RATio[:
VALue]
<value>
Lower limit value for power ratio.
Suffix:
<Measurement>
.
1...100
<DirectionalChannel> 1..2
Parameters:
<value>
Range:
1e-18 to 1e18
*RST:
1e-2
Default unit: -
Manual operation:
See
"Forward Lower Limit, Reflection Lower Limit"
CALCulate<Measurement>:LIMit<DirectionalChannel>:LOWer[:DATA][:POWer]
<value>
Lower limit value for power value.
Suffix:
<Measurement>
.
1...100
<DirectionalChannel> 1..2
Parameters:
<value>
Range:
1e-15 to 1e12
*RST:
1e-9
Default unit: W
Manual operation:
See
"Forward Lower Limit, Reflection Lower Limit"
CALCulate<Measurement>:LIMit<DirectionalChannel>:UPPer:STATe
<state>
Enables or disables the checking of the upper limit.
CALCulate