![Rohde & Schwarz 1430.0105K02 User Manual Download Page 118](http://html1.mh-extra.com/html/rohde-and-schwarz/1430-0105k02/1430-0105k02_user-manual_1477792118.webp)
Remote Control
R&S
®
NRT2
118
User Manual 1178.5550.02 ─ 04
Parameters:
<value>
Range:
-1e18 to 1e18
*RST:
1.0
Default unit: -
Manual operation:
See
"Forward Scale Lower Limit, Reflection Scale Lower Limit"
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA]:RATio:
RFRatio
<value>
Lower limit value for ratio of forward/reverse power bargraph display.
Suffix:
<Measurement>
.
1...100
<DirectionalChannel> 1..2
Parameters:
<value>
Range:
0.0 to 100.0
*RST:
0.0
Default unit: pct
Manual operation:
See
"Forward Scale Lower Limit, Reflection Scale Lower Limit"
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA]:RATio:
RLOSs
<value>
Lower limit value for return loss bargraph display.
Suffix:
<Measurement>
.
1...100
<DirectionalChannel> 1..2
Parameters:
<value>
Range:
-200.0 to 200.0
*RST:
-200.0
Default unit: dB
Manual operation:
See
"Forward Scale Lower Limit, Reflection Scale Lower Limit"
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA]:RATio:
SWR
<value>
Lower limit value for SWR bargraph display.
Suffix:
<Measurement>
.
1...100
<DirectionalChannel> 1..2
CALCulate