Remote Control
R&S
®
NRT2
155
User Manual 1178.5550.02 ─ 04
[SENSe<Sensor>:]FUNCtion:CONCurrent
<concurrent>
This command defines whether several measurement functions may be simultaneously
activated.
Parameters:
<concurrent>
ON
Two measurement functions may be simultaneously active. If
two measurement functions are mutually exclusive, the error
message. –221 "Settings conflict“ is generated and the first set-
ting retained. All
POW:FORW
and
POW:ABS
functions are mutu-
ally exclusive. This applies also to the
POW:REV
and
POW:S11
functions.
OFF
Only a single function can be active. If a new measurement
function is switched on, the previously active function is switched
off automatically.
*RST:
ON
Example:
SENS2:FUNC:CONC ON
[SENSe<Sensor>:]FUNCtion:OFF:ALL<Channel>
This command switches off all measurement functions referring to a specific channel
no. <m>, i.e.
SENSe<Sensor>:Function:OFF:ALL1
switches off all forward mea-
surement functions,
SENSe<Sensor>:Function:OFF:ALL2
switches off all mea-
surement functions in the reverse channel.
The command is a function call and therefore has no *RST-value.
Suffix:
<Channel>
.
1...2
Example:
SENS1:FUNC:OFF:ALL1
Usage:
Event
[SENSe<Sensor>:]FUNCtion:OFF[:FUNC]
<function>
This command switches off a specified measurement function. If the command is in the
form of a query, the headers of all switched-off measurement functions will be returned
in the sequence defined under
[SENS<n>]:FUNC:ON
.
The command is a function call or query and therefore has no *RST value.
Setting parameters:
<function>
SENSe