ProteOn XPR36 System | Glossary
252
Injection
Process used to introduce a sample into the flow cell starting with a
needle wash, followed by sample withdrawal, sample injection, and
another needle wash
Injection Alignment
Process of aligning the start of multiple injections generated either by
quasi-simultaneous sample injections or sequential sample injections
Injection Quality
Parameter set to control the number of bubbles separating the
injected sample from the running buffer in an injection step. Options
are: minimum (1 bubble), medium (2 bubbles), and maximum
(3 bubbles)
Injection Time
See
Contact Time
Instrument Settings
Global instrument settings that include the autosampler temperature,
sensor chip temperature, default flow rate, and standby flow rate.
The default flow rate and the standby flow rate are not user editable
Interaction
See
Biomolecular Interactio
n
Interaction Analysis
Analysis of biomolecular interaction data (kinetics, equilibrium, etc.)
using the ProteOn XPR36 system
Interaction Array
Arrangement, in 6 x 6 format, of 36 interaction spots formed when six
analyte samples flow orthogonally over six channels of immobilized
ligand on the surface of the sensor chip, in the ProteOn XPR36
instrument
Interaction Spot
One of up to 36 sites on the ProteOn XPR36 sensor chip surface
where a biomolecular interaction is measured
Intercept
Intersection of the data with either axis (X or Y) of the graph
Interspot Reference
One of 42 spots within the analyte channels used for referencing.
These are sites that were not exposed to ligand during the
immobilization process. Interspot references can be used in place of
or as a complement to a reference channel
Instrument
ProteOn XPR36 system component that houses the microfluidics
system, optical detection system, tubing, and associated controls
etc., for the purpose of interaction analysis
k
a
See
Association Rate Constant
k
d
See
Dissociation Rate Constant
K
D
See
Equilibrium Constant
Kinetics
Reaction rate, or rate of change, of a reaction or interaction
Langmuir
Simple 1:1 bimolecular interaction
Langmuir Mass
Transfer
Simple 1:1 bimolecular interaction, in which analyte diffusion to the
surface is slower than the interaction itself
Summary of Contents for XPR36
Page 1: ...ProteOn XPR36 Protein Interaction Array System Protein Interaction Analysis User Manual...
Page 2: ......
Page 3: ...ProteOn XPR36 Protein Interaction Array System Version 3 1 User Manual...
Page 4: ......
Page 10: ...ProteOn XPR36 System viii...
Page 166: ...ProteOn XPR36 System Analysis 148...
Page 188: ...ProteOn XPR36 Maintenance 170...
Page 194: ...ProteOn XPR36 System ProteOn System Troubleshooting 176...
Page 226: ...ProteOn XPR36 System A ProteOn XPR36 Instrument and Peripherals 208...
Page 250: ...ProteOn XPR36 System E Ordering Information 232...
Page 264: ...ProteOn XPR36 System F Security Edition Configuration Guide 246...
Page 276: ...ProteOn XPR36 System Glossary 258...
Page 287: ......