PART 1: CX-Programmer
CHAPTER 4 – Reference
OMRON
CX-Programmer _Page 64
The dialog can be displayed in two forms, either:
simple dialog mode
or
detailed dialog mode
. The default
mode can be set in the
Diagram
tab in the
Options
dialogue. To change the
simple dialog mode
to a
detailed
dialog mode
, select
Detail
pushbutton.
Use the following procedure to edit instructions in
simple dialog mode
.
1, 2, 3…
1. Double-click on the instruction field in the Ladder program. The Edit Instruction
dialogue is displayed.
2. Enter an instruction, either by name or by number. When a correct number has been
entered (of the correct number of digits for the PLC type), the instruction name is
automatically substituted. To insert an instruction with immediate Refresh properties,
apply an exclamation mark (‘!’) to the beginning of the instruction. To insert a
differentiated instruction, apply a ‘@’ symbol to differentiate up or a ‘%’ symbol to
differentiate down at the beginning of the instruction. When the
Show with comment
dialog
option is selected in the
Options
dialog, a comment dialog will appear after
entering an address or a symbol name.
Note:
Check the
Show with comment dialog
option in the
Diagram
tab of the
Options
dialogue to display a comment dialogue. The dialogue is displayed after the OK
pushbutton is selected on the
Contact
or
Coil
dialogue.
3. Enter operands in the same text box with a space between the instruction and each
operand (see below for more details about entering operands).
4. Select
the
OK
pushbutton to complete the operation. Select the
Cancel
pushbutton to
abort the operation.
Use the following procedure to edit instructions in
detailed dialog mode
.
1, 2, 3…
1. Double-click on the instruction field in the Ladder program. The Edit Instruction
dialogue is displayed.
2. Enter an instruction, either by name or by number. When a correct number has been
entered (of the correct number of digits for the PLC type), the instruction name is
automatically substituted. To insert an instruction with Immediate Refresh properties,
apply an exclamation mark (‘!’) to the beginning of the instruction. To insert a
differentiated instruction, apply a ‘@’ symbol to differentiate up or a ‘%’ symbol to
differentiate down at the beginning of the instruction.
Alternatively, click the
Find Instruction
pushbutton. The Find Instruction dialogue is
displayed providing a list of possible instructions. Those instructions not available for the
selected PLC are displayed in brackets. Select an Instruction by using the
Groups
and
Instruction
fields and select the
OK
pushbutton to return to the Edit Instruction dialogue.
The
Availability
pushbutton on the Find Instruction dialogue displays the PLC
Instruction Support dialogue that lists all PLCs for which the selected instruction in the
Find Instruction dialogue is available. Select the Close pushbutton to remove the PLC
Instruction Support dialogue.
Summary of Contents for Sysmac WS02-CXPC1-EV3
Page 1: ...Cat No W414 E1 01 SYSMAC...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Page 4: ......
Page 6: ......
Page 7: ...PART1 CX Programmer...
Page 8: ......
Page 24: ......
Page 34: ......
Page 106: ......
Page 130: ......
Page 131: ...PART 2 CX Server PLC Tools...
Page 132: ......
Page 136: ......
Page 158: ......
Page 168: ......
Page 194: ......
Page 206: ......
Page 250: ......
Page 298: ......
Page 304: ......
Page 305: ...PART 3 CX Server Runtime...
Page 306: ......
Page 310: ......
Page 338: ......
Page 344: ......
Page 378: ......
Page 384: ......
Page 388: ......