PART 2: CX-Server PLC Tools
CHAPTER 10 – Data Link Editor
OMRON
CX-Server PLC Tools_Page 100
Automatically Set Data Links
This section explains how to make the settings for automatically set data links.
Make the settings in the Automatic Datalink (Controller Link) or Automatic Datalink (SYSMAC LINK) dialog
box.
First make the settings for data link operation at PLC startup, and for the automatic data link setup parameters,
and then transfer the data to the startup node.
When using automatically set data links, there is no need to create data link tables with the Data Link Editor.
Procedure Through Data Link Startup
Start the data links.
Datalink Component Data Link Status
operation
1)
Online | Status
2) Select the
Run
option in the
Operation
field, and then click the
Set
button.
Turn ON the power to the PLC.
Create a CX-Server file (*.CDM) for connecting online.
1) Select
New
from the
Project
menu and save the setting under a file name.
2) Select
Add Device
from the
Project
menu, and register the PLC (as a node on the
network).
Connect online to the startup node PLC (registered as a node on the network).
(Select the startup node PLC and then select
PLC | Open
from the CX-Net.)
Set the automatic data link setup parameters.
1) Select
Data Link | Setup
.
2) Select
Controller Link Unit
or
SYSMAC LINK Unit
as the Communications Unit
mounted to the PLC. (For the local network only, i.e. when the network address is 0.)
3) Select
PLC | Setup
in the Datalink Component window.
4) Select
Automatic
in the
Generation Type
field in the Automatic Datalink dialog box,
and make the settings for the automatically set data link areas (start word, size, and
nodes participating in data links, for Area 1 and Area 2).
4) To have the data links started when
the PLC is started, set
Start
for the
status at startup.
Transfer the automatic data link setup parameters to the startup node. (Click the
Write
button.)
Summary of Contents for Sysmac WS02-CXPC1-EV3
Page 1: ...Cat No W414 E1 01 SYSMAC...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Page 4: ......
Page 6: ......
Page 7: ...PART1 CX Programmer...
Page 8: ......
Page 24: ......
Page 34: ......
Page 106: ......
Page 130: ......
Page 131: ...PART 2 CX Server PLC Tools...
Page 132: ......
Page 136: ......
Page 158: ......
Page 168: ......
Page 194: ......
Page 206: ......
Page 250: ......
Page 298: ......
Page 304: ......
Page 305: ...PART 3 CX Server Runtime...
Page 306: ......
Page 310: ......
Page 338: ......
Page 344: ......
Page 378: ......
Page 384: ......
Page 388: ......