CHAPTER 4 – PLC Setup Component
CX-Server PLC Tools_Page 27
CHAPTER 4
PLC Setup Component
This chapter describes the PLC Setup component and the procedures involved in changing a PLC’s settings both
offline and online.
The PLC Setup component allows the PLC settings to be entered for individual C-series PLCs, CV-series PLCs
or CS1-series PLCs. More than one PLC Setup component can be opened at any one time allowing a number
of PLCs to be configured simultaneously.
Once a PLC has been defined in a project in terms of name, device type and network type, changing various
settings allows the PLC behaviour to be altered. Options can also be selected to check the PLC is functioning
correctly.
The tabbed PLC settings component shows only options available for the selected PLC. Some options will be
greyed out in instances where they are not applicable to the PLCs current state.
The status bar displays the PLC and CPU type and the operational mode of the PLC.
Note:
When configuring a PLC it is advisable to have the PLC operational manual available
for reference. A warning is displayed before any changes are made to a PLC’s
current state. This gives the option of cancelling the procedure.
Note:
The information provided in this chapter is not definitive because of the wide variety
of PLCs and their differing nature - even within the same PLC series. Consult the
relevant PLC operating manual for specific PLC settings information.
The PLC Setup component can be forced to stay as the top window by selecting the
Always on top
option from
the
Options
menu.
For Moving, resizing, maximising, minimising and closing windows, refer to Microsoft Windows online help.
Access to the PLC Setup component is from the invoking application and also via the CX-Net Network
Configuration Tool
,
refer to
Chapter 8 - CX-Net Network Configuration Tool
for further information.
To close the PLC Setup dialogue, select the
Close
button in the title bar.
CS1-Series PLC Settings
The following paragraphs describe the features of the PLC Setup component associated with CS1-series PLCs.
Refer to
Chapter 4 - PC to PLC Communications
for details of transferring PLC setup information to and from
the PLC.
The common
Set Default
option resets PLC Setup component values to the default settings.
PLC Startup
The
PLC Startup
tab of the PLC Setup component allows certain PLC settings to be made which always take
effect on startup (until they are explicitly altered). Use the following procedure to apply settings in the
PLC
Startup
tab.
Startup Hold
The Hold area in the PLC’s Work Area Memory retains the status when either the operating mode is changed,
power is interrupted or the PLC operation is stopped. You can select one or all the following options for the hold
area to retain.
1, 2, 3…
1.
Force Status Hold Bit
- Specifies that the status of the forced status hold bit is to be
maintained (ticked) or reset to OFF when power is next turned on.
2.
IOM Hold Bit
- Specifies that the status of the IOM hold bit is to be maintained (ticked)
or reset to OFF when power is next turned on.
Mode
This selects the default PLC operation mode when the PLC is powered on:
♦
Program
- Select this for online programming when the PLC is powered on.
Summary of Contents for Sysmac WS02-CXPC1-EV3
Page 1: ...Cat No W414 E1 01 SYSMAC...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Page 4: ......
Page 6: ......
Page 7: ...PART1 CX Programmer...
Page 8: ......
Page 24: ......
Page 34: ......
Page 106: ......
Page 130: ......
Page 131: ...PART 2 CX Server PLC Tools...
Page 132: ......
Page 136: ......
Page 158: ......
Page 168: ......
Page 194: ......
Page 206: ......
Page 250: ......
Page 298: ......
Page 304: ......
Page 305: ...PART 3 CX Server Runtime...
Page 306: ......
Page 310: ......
Page 338: ......
Page 344: ......
Page 378: ......
Page 384: ......
Page 388: ......