OMRON
PART1: CX-Programmer
CX-Programmer_Page (xi)
n
Verification
Program Verification Offline or Online
Previous version (Ver. 3.0)
New version (Ver. 3.1)
Program verification was possible only
between the current project and the PLC.
Program verification is possible offline between the current project and a
closed project file. (Select
Compare Program
from the
File
menu and select
the file to be compared.) The results of verification can be saved to a file in
CSV format. Refer to
Chapter 2
of
PART 1
for details (page 23).
Added or omitted instructions were not
displayed in verification results (if added
or omitted instructions were
encountered, the verification results for
the rest of the program would show that
the programs were completely different).
Verification results are displayed by section and mnemonic, including added
or omitted instructions. Jumping is also possible from mnemonic verification
results to the corresponding locations in ladder view. Refer to
Chapter 2
of
PART 1
for details (page 23).
Displaying Dialog Box for Verification or Transfer when Going Online
Previous version (Ver. 3.0)
New version (Ver. 3.1)
Nothing was displayed before going
online.
If a checkmark is placed in the
Prohibit the online operations until the PC and
PLC data matches
checkbox on the
PLCs
tab page that appears when
Tools
| Options
is selected, an
Online Action
dialog box to select either verifying or
transferring data will be displayed. Depending on the selection, before going
online, the program will be verified between the CX-Programmer and the PLC,
the program will be transferred to the PLC, or the program will be transferred
from the PLC. Refer to
Chapter 4
of
PART 1
for details (page 71).
n
Unit Online Replacement
Unit Online Replacement for CS1D or CVM1D PLCs
Previous version (Ver. 3.0)
New version (Ver. 3.1)
With a CS1D or CVM1D CPU Unit, hot swapping (i.e., online replacement) is
possible during operation for Basic I/O Units and, for the CS1D, Special I/O
Units and CPU Bus Units as well. Open the I/O tables for the project, select the
Unit to be replaced, and select
Hot Swap
from the
Options
menu. Click the
Start Hot Swap
button, remove the old Unit, mount the new Unit and click the
End Hot Swap
button. Perform this operation for each Unit to be replaced.
Refer to
Chapter 3
of
PART 2
for details (page 24).
Note: Online replacement is possible for a CS1D or CVM1D CPU Unit in any
operating mode. Use the following settings in the
Change PLC
dialog box.
CPU Unit being used
PLC type selection list
CPU Unit model
CS1D
CS1H-H
CPU65 or CPU67
Unit online replacement for CS1D or
CVM1D CPU Units was possible only
from a Programming Console and was
not possible from the CX-Programmer.
(C2000H I/O Unit online replacement
was possible.)
CVM1D CVM1-V2 CPU21
Summary of Contents for Sysmac WS02-CXPC1-EV3
Page 1: ...Cat No W414 E1 01 SYSMAC...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Page 4: ......
Page 6: ......
Page 7: ...PART1 CX Programmer...
Page 8: ......
Page 24: ......
Page 34: ......
Page 106: ......
Page 130: ......
Page 131: ...PART 2 CX Server PLC Tools...
Page 132: ......
Page 136: ......
Page 158: ......
Page 168: ......
Page 194: ......
Page 206: ......
Page 250: ......
Page 298: ......
Page 304: ......
Page 305: ...PART 3 CX Server Runtime...
Page 306: ......
Page 310: ......
Page 338: ......
Page 344: ......
Page 378: ......
Page 384: ......
Page 388: ......