OMRON
PART1: CX-Programmer
CX-Programmer_Page (xii)
n
I/O Table Editing Functions
Specifying Slot Start Address when Editing I/O Tables for Slots Other than First Rack Slots
Previous version (Ver. 3.0)
New version (Ver. 3.1)
For CS- and CJ-series PLCs, the start
address for each Rack could be set (but
the start address could not be set for
each slot).
For CS1-H, CJ1-H, CJ1M, and CS1D CPU Units in the CS- and CJ-series PLCs,
Options
|
Rack/Slot Start Addres
s can be selected during I/O table editing to
set the start address for a specific Rack and slot (in addition to the start address
for each Rack).
This can be used, for example, to allocate fixed addresses to Input Units and
Output Units. Refer to
Chapter 3
of
PART 2
for details (page 25).
Note: The start address information set for Racks and slots can be downloaded
and uploaded for the CPU Unit.
Previous version (Ver. 3.0)
New version (Ver. 3.1)
When editing I/O tables, unit number,
number of allocated unit numbers,
number of input words, number of output
words had to be set for Special I/O Units
and CPU Bus Units, and the unit
numbers and number of allocated unit
numbers were displayed in the I/O Table
window, but the number of input words
and the number of output words were not
displayed in the I/O Table window.
When editing I/O tables, the number of input words and number of output words
are displayed in the I/O Table window for Special I/O Units and CPU Bus Units
that have been set (Out: , In: ). Refer to
Chapter 3
of
PART 2
for details
(page 25).
n
Other Changes
Data Transfer and Verification for a ROM Writer
Previous version (Ver. 3.0)
New version (Ver. 3.1)
With the C-series PLCs, any of the following methods can be used for data transfer and
verification with a ROM Writer.
•
Using the CX-Programmer, transfer the program from the computer to the ROM
Writer.
•
Transfer program from the ROM Writer to a CX-Programmer project.
•
Verify programs between CX-Programmer and ROM Writer.
•
Create Intel Hex format files from CX-Programmer programs.
•
Input from an Intel Hex format file to the CX-Programmer project.
Refer to
Chapter 4
of
PART 1
for details (page 79).
Note: The data transferred for each PLC is listed below.
PLC
Data
C1000H/2000H
Program, I/O tables, SYSMAC NET data link tables, battery
error detection method
C200H
Program, I/O tables, Fixed DM, battery error detection method
C200HS
Program, I/O tables, PLC Setup, Expansion DM, expansion
instructions
CQM1, CQM1H
Program, PLC Setup, expansion instructions
Transfer and verification were
not possible for a ROM Writer.
C200HX/HG/HE (-Z)
Program, I/O tables, PLC Setup , Expansion DM, expansion
instructions
Summary of Contents for Sysmac WS02-CXPC1-EV3
Page 1: ...Cat No W414 E1 01 SYSMAC...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Page 4: ......
Page 6: ......
Page 7: ...PART1 CX Programmer...
Page 8: ......
Page 24: ......
Page 34: ......
Page 106: ......
Page 130: ......
Page 131: ...PART 2 CX Server PLC Tools...
Page 132: ......
Page 136: ......
Page 158: ......
Page 168: ......
Page 194: ......
Page 206: ......
Page 250: ......
Page 298: ......
Page 304: ......
Page 305: ...PART 3 CX Server Runtime...
Page 306: ......
Page 310: ......
Page 338: ......
Page 344: ......
Page 378: ......
Page 384: ......
Page 388: ......