PART 3: CX-Server Runtime
OMRON
CHAPTER 3 – Communications
CX-Server Runtime_Page 25
2. Click on the associated
Settings
pushbutton in the Change PLC dialog.
3. In
the
Network
tab, define the
FINS Destination Address
by entering the
Network
and
Node
.
4. Set
the
Response Timeout(s)
to adjust for a slow network as necessary.
5. Enter the Frame Length in the
Frame Length
field. Refer to
Controller Link
documentation
for further information.
6. In
the
Driver
tab, set the appropriate setting for the
Shared RAM Address
,
Interrupt Level
and
Baud Rate
fields. Refer to
Controller Link documentation
for further information.
7. Select an appropriate
Node
and
Unit
for the Network address.
8. Select
the
OK
pushbutton to save the settings or select the
Cancel
pushbutton to abort the
operation.
Ethernet
Ethernet is a commonly used network capable of achieving a high rate of data transmission.
An NIC board must be installed inside the computer and TCP/IP protocols must be added and configured.
Use the following procedure to configure Ethernet.
1, 2, 3…
1. Ensure the Network Type is Ethernet.
2. Click on the associated
Settings
pushbutton in the Change PLC dialog.
3. In
the
Network
tab define the
FINS Source Address: Network
field by entering the
Network Address.
4. Check
the
Network
and
Node
addresses for the PLC and enter them in the
FINS
Destination Address: Network
field and
Node
field respectively.
5. Set
the
Response Timeout(s)
to adjust for a slow network.
6. Enter the Frame Length in the
Frame Length
field.
7. In
the
Driver
tab, check the Workstation Address and enter it in the
Workstation: Node
Number
field. Alternatively, select the
Auto Detect
setting to automatically determine the
workstation address.
8. Check the PLC IP address and enter it in the
PLC: IP
Address field.
9. Check the FINS UDP Port Number and enter it in the
PLC: Port Number
field.
10. Select the
OK
pushbutton to accept the settings. Select the
Cancel
pushbutton to abort
the operation.
Note:
If using a subnet mask which is not 255.255.255.0 you will need to add the IP Address of the
PC wishing to connect, into the Ethernet unit. Do this using the I/O table.
PROM Writer
PROM Writer is a device allowing Programmable Read Only Memory (PROM) to be written to.
The following connection is required:
♦
RS232 connection via a standard serial port on the computer (COM1 etc.).
The
Driver
tab of the Network Settings
dialog is similar to that belonging to SYSMAC WAY, however, the
transmission conditions should be set to:
♦
Baud Rate = 9600
♦
Data Bits = 8
♦
Parity = none
♦
Stop Bits = 1
♦
or those of the particular PROM writer unit being used.
Summary of Contents for Sysmac WS02-CXPC1-EV3
Page 1: ...Cat No W414 E1 01 SYSMAC...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Page 4: ......
Page 6: ......
Page 7: ...PART1 CX Programmer...
Page 8: ......
Page 24: ......
Page 34: ......
Page 106: ......
Page 130: ......
Page 131: ...PART 2 CX Server PLC Tools...
Page 132: ......
Page 136: ......
Page 158: ......
Page 168: ......
Page 194: ......
Page 206: ......
Page 250: ......
Page 298: ......
Page 304: ......
Page 305: ...PART 3 CX Server Runtime...
Page 306: ......
Page 310: ......
Page 338: ......
Page 344: ......
Page 378: ......
Page 384: ......
Page 388: ......