PART 2: CX-Server PLC Tools
CHAPTER 4 – PLC Setup Component
OMRON
CX-Server PLC Tools_Page 34
1, 2, 3…
1. Check
the
Watch Cycle Time
setting and set the watch cycle time if enabled for the PLC;
the default is 1000ms.
2. Check
the
Power Off Interrupt
setting, and set if enabled for the PLC; the default is 0ms.
3. Set
the
Cycle Time
setting to define the time interval for cycles.
4. Set
the
Scheduled Interrupt Interval
setting to schedule interrupts to occur at regular
intervals; either every 10ms or a specific value can be set.
Hold
The
Hold
tab of the PLC Setup component allows the Hold area of the PLC’s Work Area memory to be defined.
Use the following procedure to apply settings in the
Hold
tab.
1, 2, 3…
1. Check
the
Enable Hold Area
setting to enable the Hold area and select its
Start
and
End
Address
settings.
2. Check the required racks from the
CPU
field.
3. Check the required Sysbus/2 remote master from the
Sysbus/2 Remote Master
field.
4. Check the required Sysbus remote master from the
Sysbus Remote Master
field.
C-Series PLC Settings
The following paragraphs describe the features of the PLC Setup component associated with C-series PLCs.
Refer to
Chapter 4 - PC to PLC Communications
for details of transferring PLC setup information to and from
the PLC.
The common
Set Default
option resets PLC Setup component values to the default settings.
PLC Startup
The
PLC Startup
tab of the PLC Setup component allows certain PLC settings to be made which always take
effect on startup (until they are explicitly altered). Use the following procedure to apply settings in the
PLC
Startup
tab.
Mode
This option selects the default PLC operation mode when the PLC is powered on.
1, 2, 3…
1.
Program
– Select this for online programming when the PLC is powered on.
2.
Monitor
– Select this to start monitoring the running program when the PLC is powered
on.
3. Run
– Select this to run the PLC’s program when the PLC is powered on.
4. Pre-Powerdown
mode
– In this mode the PLC uses the operating mode last used before
the power was turned off.
5.
Use Programming Console
– This is the default setting that allows you to select the
operating mode when online.
SIOU
The SIOU Area DM settings are highly PLC specific and are dependent upon PLC selected and the SIOU mode.
Refer to the online help for detailed information.
IOM
This option specifies that the status of the IOM hold bit is to be
reset
to OFF (ticked) or
maintained
when power
is next turned on.
Forced Status
This option specifies that the status of the forced status hold bit is to be
reset
to OFF (ticked) or
maintained
when power is next turned on.
Console Language
Select the Console language to either English or Japanese as appropriate (CPM1/1A only).
Summary of Contents for Sysmac WS02-CXPC1-EV3
Page 1: ...Cat No W414 E1 01 SYSMAC...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Page 4: ......
Page 6: ......
Page 7: ...PART1 CX Programmer...
Page 8: ......
Page 24: ......
Page 34: ......
Page 106: ......
Page 130: ......
Page 131: ...PART 2 CX Server PLC Tools...
Page 132: ......
Page 136: ......
Page 158: ......
Page 168: ......
Page 194: ......
Page 206: ......
Page 250: ......
Page 298: ......
Page 304: ......
Page 305: ...PART 3 CX Server Runtime...
Page 306: ......
Page 310: ......
Page 338: ......
Page 344: ......
Page 378: ......
Page 384: ......
Page 388: ......