PART 2: CX-Server PLC Tools
OMRON
CHAPTER 3 – IO Table Component
CX-Server PLC Tools_ Page 19
Counters, Position Controller, Numerical Control and ASCII Units
Use the following procedure to apply unit settings to Counters, Position Controllers, Numerical Control and
ASCII units.
1, 2, 3…
1. Allocate a slot to be a Counter unit, Position Controller unit, Numerical Control unit or
ASCII unit. The Enter SIOU Details dialogue is displayed.
2. Enter valid settings for the
Unit Number
field,
Address per Unit
field,
Input Words
field
and
Output Words
field. Valid settings exclude those settings that have already been
used.
3. Select
the
OK
pushbutton to complete the operation or the
Cancel
pushbutton to abort the
operation.
Additionally for Counters, Numerical Control and ASCII units, for CV-series PLCs and CS1-series PLCs, the
CIO and DM Address range need to be specified; refer to
Chapter 3 - Software Switches
for further information.
Interrupt Units
Interrupt units are automatically assigned until the maximum number of units has been reached.
Sysmac-Bus Master Unit and Remote Terminals
If the
Sysmac-Bus Master
option is selected from the context menu, the hierarchy in the IO Table component can
be further expanded to expose the Remote Terminals and IO Terminals that form part of the SYSMAC-BUS
option. Use the following procedure to apply unit settings to Sysmac-Bus Master.
1, 2, 3…
1. Allocate a slot to be a Sysmac-Bus Master unit. The Enter RM Number dialogue is
displayed.
2. Select a unit number from the
Unit Number
field, either 0 or 1.
3. Select
the
OK
pushbutton to complete the operation or the
Cancel
pushbutton to abort the
operation.
The Sysmac-Bus Master unit provides two types of slave units that can be applied to the slave rack in the same
manner as a normal rack:
♦
C500H Remote Terminal (RT);
♦
C200H Remote Terminal (RT).
Any units on the slave racks or other Remote IO Units connected to the master are allocated IO words according
to the slot where the master is located.
For C1000H and C2000H PLCs, Word multipliers are required to set the base address of IO Terminals on each
SYSMAC-BUS Remote Master.
SIOU/Communications Units
SIOU/Communications Units can only be set up for CV-series PLCs and CS1-series PLCs.
For CV-series PLCs SIOU/Communications Units the following Unit Setup and Software Switches setup can be
performed:
♦
Basic (Software Switches setup only);
♦
CompoBus/D Master (Software Switches setup only);
♦
Controller Link;
♦
Ethernet;
♦
Host Link;
♦
ISA Board Unit (Software Switches setup only);
♦
ME-Net (Software Switches setup only);
♦
Mini-map (Software Switches setup only);
♦
M-Net (Software Switches setup only);
♦
Motion Controller (Software Switches setup only);
♦
PC (Software Switches setup only);
♦
Syslink;
Summary of Contents for Sysmac WS02-CXPC1-EV3
Page 1: ...Cat No W414 E1 01 SYSMAC...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Page 4: ......
Page 6: ......
Page 7: ...PART1 CX Programmer...
Page 8: ......
Page 24: ......
Page 34: ......
Page 106: ......
Page 130: ......
Page 131: ...PART 2 CX Server PLC Tools...
Page 132: ......
Page 136: ......
Page 158: ......
Page 168: ......
Page 194: ......
Page 206: ......
Page 250: ......
Page 298: ......
Page 304: ......
Page 305: ...PART 3 CX Server Runtime...
Page 306: ......
Page 310: ......
Page 338: ......
Page 344: ......
Page 378: ......
Page 384: ......
Page 388: ......