PART 1: CX-Programmer
OMRON
CHAPTER 4 – Reference
CX-Programmer _Page 63
Use the following procedure to force bits.
1, 2, 3…
1. Obtain the Ladder program and select the element to be forced.
2. Select
Force
from the context sensitive menu, followed by
On
,
Off
or
Cancel
.
Select
Force
from the context sensitive menu, followed by
Cancel All
to cancel all forced bits so that current
values are free to be changed by the PLC program.
Once an element has been forced, a symbol is placed in the Ladder program to indicate that its status has been
forced.
♦
Set
. Set is available from the contact or coil context sensitive menu. The bit can be set to 1 or 0 by
selecting the
Set
option from the contact or coil context sensitive menu followed by
Value
,
To 1
or
To 0
.
♦
Differentiate
.
Differentiate is available from the contact or coil context sensitive menu, performing the
same functions as that within the Edit Contact dialogue. Select
Differentiate
from the context sensitive
menu, followed by
Up
or
Down
.
♦
Immediate
.
Immediate Refresh is available from the contact or coil context sensitive menu, performing the
same functions as that within the Edit Contact dialogue. Select
Immediate Refresh
from the context
sensitive menu.
♦
Differential Monitor
.
Differential Monitor is for bits that are not accessible for conventional monitoring
(for instance, values changing too rapidly), but which can be monitored via the Differential Monitor
dialogue. The dialogue permits the selection of a particular bit to monitor, whether it is monitored against
its falling or rising edge, and whether sound should be used when the bit value changes.
Use the following procedure to apply the differential monitor.
1, 2, 3…
1. Select the Program object in the project workspace to display the Ladder program in the
Diagram Workspace.
2. Select
the
Work On-line
button from the toolbar. A confirmation message is displayed:
select the
Yes
pushbutton to connect to the PLC.
3. Select
the
Run Mode
button from the toolbar. Differential monitoring can only be
accomplished in this PLC operating modes and Monitor mode.
4. Select the contact or coil to monitor.
5. Select
the
Differential Monitor
button from the toolbar. The Differential Monitor
dialogue is displayed.
6. The address associated with the contact or coil selection is displayed in the
Address
field.
Select an
Edge
option.
7. Select
the
Sound
setting to retrieve audio whilst monitoring.
8. Select
the
Start
pushbutton to start monitoring. The
Start
pushbutton becomes a
Stop
pushbutton.
9. Select
the
Stop
pushbutton to cancel monitoring. Select the
Close
pushbutton to exit the
dialogue.
10. Select the
Toggle PLC Monitoring
button from the toolbar to stop monitoring.
Instruction Editing
The Edit Instruction dialogue allows an instruction to be selected and entered into the Ladder program.
Summary of Contents for Sysmac WS02-CXPC1-EV3
Page 1: ...Cat No W414 E1 01 SYSMAC...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Page 4: ......
Page 6: ......
Page 7: ...PART1 CX Programmer...
Page 8: ......
Page 24: ......
Page 34: ......
Page 106: ......
Page 130: ......
Page 131: ...PART 2 CX Server PLC Tools...
Page 132: ......
Page 136: ......
Page 158: ......
Page 168: ......
Page 194: ......
Page 206: ......
Page 250: ......
Page 298: ......
Page 304: ......
Page 305: ...PART 3 CX Server Runtime...
Page 306: ......
Page 310: ......
Page 338: ......
Page 344: ......
Page 378: ......
Page 384: ......
Page 388: ......