PART 2: CX-Server PLC Tools
OMRON
CHAPTER 4 – PLC Setup Component
CX-Server PLC Tools_ Page 37
comparison control that is not affected by the PLCs cycle time. High-speed counter signals can be input to
CPU bits 00000 through 00002. In incrementing mode, input 00001 can be used as a regular input.
High Speed Counter/Synchronised Pulse Control
Select the appropriate option to determine the parameters of the high speed counter. If the option ‘Don’t use
either function’ is selected the counter is disabled and the Counter Reset and Counter Mode option are disabled.
Counter Reset
Select the counter reset mode of operation, either Z phase and software reset or Software reset only.
Counter Mode
Select the appropriate option to determine the counters mode of operation.
Device Net
I/O Link Refresh Area
Note:
This tab is only available for the CPM2*-S* PLCs.
1, 2, 3…
1.
Standard
- Select this button to set the standard/default settings for the I/O Refresh Area.
2.
Custom
- Select this button to make your own settings.
3. Write:
These setting are the same as Read, but without the option of selecting the 'AR'
memory area.
♦
Area
- This option defaults to IR area 1, but can be set to IR area 2, DM area, LR area or HR
area.
♦
Address
- This is the beginning address number.
♦
Size
- The default is 0. However, if the size is 0 for Write, then the size for Read must be 1,
or vice versa. Any custom setting's maximum value is determined by what the Area and
Address values before it were set to. For example, if IR area 1 is selected, and the maximum
address is specified (in this case max = 49), then the maximum size is 1. (The size value is
specified in Words).
4.
Read:
These setting are the same as Write, but with the additional option of being able
to selecting the 'AR' memory area for reading.
♦
Area
- This option defaults to IR area 1, but can be set to IR area 2, DM area, LR area or HR
area.
♦
Address
- This is the beginning address number.
♦
Size
- The default is 0. However, if the size is 0 for Write, then the size for Read must be 1,
or vice versa. Any custom setting's maximum value is determined by what the Area and
Address values before it were set to. For example, if IR area 1 is selected, and the maximum
address is specified (in this case max = 49), then the maximum size is 1. (The size value is
specified in Words).
PLC Status
These options determine the status of the PLC.
Append PLC Status on top of IN data
- Select this button to Append PLC Status on top of IN data, or choose 'Do
not append PLC Status'.
Do not append PLC Status
- Select this button to not append PLC Status on top of IN data, or choose 'Append
PLC Status on top of IN data'.
PC to PLC Communications
The PLC Setup component permits the transferring of data to and from the PLC and allows comparisons to be
made between data stored on the PC and the PLC.
Uploading PLC Settings
The
Transfer from PLC
option loads the settings from the PLC into the PLC Setup component. Use the
following procedure to upload PLC settings.
Summary of Contents for Sysmac WS02-CXPC1-EV3
Page 1: ...Cat No W414 E1 01 SYSMAC...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Page 4: ......
Page 6: ......
Page 7: ...PART1 CX Programmer...
Page 8: ......
Page 24: ......
Page 34: ......
Page 106: ......
Page 130: ......
Page 131: ...PART 2 CX Server PLC Tools...
Page 132: ......
Page 136: ......
Page 158: ......
Page 168: ......
Page 194: ......
Page 206: ......
Page 250: ......
Page 298: ......
Page 304: ......
Page 305: ...PART 3 CX Server Runtime...
Page 306: ......
Page 310: ......
Page 338: ......
Page 344: ......
Page 378: ......
Page 384: ......
Page 388: ......