The machine
cannot be lifted
1. The lift
inhibit function
is enabled
1. Disable the lift inhibit function in accordance with
section 4.2.4. Using the user interface
2. Machine
lifting circuit
ball valve is
closed
2. Open the machine lift ball valve in accordance with
the instructions in section 5.3.5. Using the machine
3. The quick
coupling is
open
3. Check the connection of the quick coupler
The machine
cannot be
lowered
1. Machine
lifting circuit
ball valve is
closed
1. Open the machine lift ball valve in accordance with
the instructions in section 5.3.5. Using the machine
2. The quick
coupling is
open
2. Check the connection of the quick coupler
3. The stoppers
are in place in
the lifting
cylinder
3. Remove the stoppers from the lifting cylinder
Hopper alarm
does not
function
1. The alarm
has been
disabled
1. Enable the alarm from the settings in accordance with
section 4.2.4.4. Settings.
The shaft
rotation guard
does not
function
1. The alarm
has been
disabled
1. Enable the alarm from the settings in accordance with
section 4.2.4.4. Settings.
Operation and maintenance manual
1.00
FX300 and FX400 SeedPilot
197 (208)