4. Press OK (2).
The system will calculate the calibration value (g/r) from the weighing result. The
calibration value (3) is displayed on the screen next to the selected memory slot.
5. Return to the Drive screen.
Figure. 6.8.4. - 155. Feed rate according to the linear actuator position
In the machine with gearbox, the linear actuator will move immediately to the
right and into place. The fertiliser target rate (1) will appear on the Drive screen.
6. Insert the cotter pins.
7. Turn the crank to bring the calibration trays to the seeding position.
8. Put the transmission cover back in place.
6.8.5. Seed calibration test in a machine without a gearbox
DANGER
If the machine is equipped with a SeedPilot or SeedPilot ISOBUS control system, switch
on the STOP ALL function in accordance with section 6.3.1. Using the STOP ALL
DANGER
Shut off the tractor, remove the key from the ignition and engage the parking brake
before running a calibration test. If the machine is equipped with middle markers, close
the middle marker shut-off valves in accordance with the instructions in section 3.4.
Using the middle marker ball valves.
1. Raise the transmission cover.