5.2.3.2. Commissioning
Figure. 5.2.3.2. - 78. Commissioning
1.
Setting the half lift height limit
The number value (%) is the height limit (from ground level) at which the half lift
stops the raising of the machine. When the set limit is reached, the machine lift is
stopped with the same valve as used for the lift inhibit function.
The factory setting is 50%. A new height limit value is set by pressing the HALF
LIFT button (1).
2.
Setting the delays for marker valves
(8) is the middle marker delay when turned on (7) is the middle marker delay
when turned off, (6) is the rear marker delay when turned on and (5) is the rear
marker delay when turned off.
The delay when turned on is the delay (in seconds) from when the machine has
been lowered to when the marker solenoid opens and the marker begins
lowering.
The delay when turned off is the delay (in seconds) from when the machine has
been raised until the marker solenoid closes and the marker begins rising.
The set default values are displayed on the screen. A new delay is set by pressing
the desired number value.
3.
Selecting a tramline reminder
The tramline reminder is active when the box (3) is checked.
When active, the tramline reminder will issue a short “beep” every 20 seconds
when making passes with a tramline.
Operation and maintenance manual
1.00
FX300 and FX400 SeedPilot
75 (208)
Summary of Contents for FX300 SeedPilot
Page 200: ...Hydraulic schematics FX300 and FX400 1 Hydraulic schematics FX300...
Page 201: ...Hydraulic schematics FX300 and FX400 2...
Page 202: ...Hydraulic schematics FX300 and FX400 3 Hydraulic schematics FX400...
Page 203: ...Hydraulic schematics FX300 and FX400 4...
Page 204: ...Electrical schematics FX300 and FX400 1 Electrical schematics...