3. SIGNALS AND WIRING
3 - 9
(2) When you use a positioning module FX
3U
-_ _MT/ES (For sink I/O interface)
Servo amplifier
(Note 1)
2 m or less
10 m or less
42
15
19
43
44
21
27
SD
EM2
SON
RES
LSP
LSN
DICOM
TLA
LG
28
(Note 7)
CN1
+
(Note 9)
MR Configurator2
CN3
(Note 10)
Power supply
(Note 2)
(Note 7)
CN1
47
DOCOM
48
ALM
23
ZSP
4
LA
5
LAR
6
LB
7
LBR
34
LG
SD
8
LZ
9
LZR
RA1
RA2
10 m or less
(Note 7)
CN1
COM3
X _ _ _
X000
RD
3
49
33
10
12
35
41
20
L
N
COM2
Y000
COM1
Y004
Y010
OP
LG
PP
OPC
NP
DICOM
DOCOM
CR
46
Programmable controller
FX
3U
-_ _MT/ES (Note 11)
S/S
24 V
0 V
Programmable
controller
power supply
2 m or less (Note 8)
24 V DC
(Note 4)
24 V DC (Note 4)
24 V DC (Note 4)
(Note 15)
(Note 12)
(Note 13)
(Note 14)
X _ _ _
INP
24
SD
2 m or less
26
MO1
30
LG
29
MO2
± 10 V DC
± 10 V DC
SD
(Note 7)
CN1
0 V to +10 V
Malfunction (Note 6)
Zero speed detection
Encoder A-phase pulse
(differential line driver)
Encoder Z-phase pulse
(differential line driver)
Encoder B-phase pulse
(differential line driver)
Control common
Plate
Plate
Plate
Plate
Forced stop 2
Servo-on
Reset
Forward rotation
stroke end
Reverse rotation
stroke end
(Note 3, 5)
(Note 5)
Analog torque limit
+10 V/maximum torque
USB cable (option)
Personal
computer
Analog monitor 1
Analog monitor 2
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...