5. PARAMETERS
5 - 20
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
Set the shape of the machine resonance suppression filter 2.
PB16
NHQ2
Notch shape
selection 2
_ _ _ x Machine resonance suppression filter 2 selection
0: Disabled
1: Enabled
0h
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _ Notch width selection
0:
Į
= 2
1:
Į
= 3
2:
Į
= 4
3:
Į
= 5
0h
x _ _ _ For manufacturer setting
0h
PB17
NHF
Shaft
resonance
suppression
filter
Set the shaft resonance suppression filter.
This is used to suppress a low-frequency machine vibration.
When you select "Automatic setting (_ _ _ 0)" of "Shaft resonance suppression filter selection" in [Pr. PB23], the value
will be calculated automatically from the servo motor you use and load to motor inertia ratio. Set manually for "Manual
setting (_ _ _ 1)".
When "Shaft resonance suppression filter selection" is "Disabled (_ _ _ 2)" in [Pr. PB23], the setting value of this
parameter will be disabled.
When you select "Enabled (_ _ _ 1)" of "Machine resonance suppression filter 4 selection" in [Pr. PB49], the shaft
resonance suppression filter is not available.
_ _ x x Shaft resonance suppression filter setting frequency selection
Refer to table 5.5 for settings.
Set the value closest to the frequency you need.
00h
_ x _ _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
x _ _ _ For manufacturer setting
0h
Table 5.5 Shaft resonance suppression filter
setting frequency selection
Setting
value
Frequency [Hz]
Setting
value
Frequency [Hz]
00
Disabled
10
562
01
Disabled
11
529
02
4500
12
500
03
3000
13
473
04
2250
14
450
05
1800
15
428
06
1500
16
409
07
1285
17
391
08
1125
18
375
09
1000
19
360
0A
900
1A
346
0B
818
1B
333
0C
750
1C
321
0D
692
1D
310
0E
642
1E
300
0F
600
1F
290
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...