6. NORMAL GAIN ADJUSTMENT
6 - 11
(b) One-touch tuning execution
POINT
For equipment in which overshoot during one-touch tuning is in the permissible
level of the in-position range, changing the value of [Pr. PA25 One-touch tuning
- Overshoot permissible level] will shorten the settling time and improve the
response.
After the response mode is selected in (a), pushing the "SET" button will start one-touch tuning.
Completing the one-touch tuning will start writing the auto-tuned parameters to the servo
amplifier.
The one-touch tuning progress is displayed with 0% to 100%.
The decimal point moves left to right in rotation during the tuning.
To switch the display to the status display during the tuning, push the "MODE" button.
One-touch tuning in
progress
Complete
(c) Stop of one-touch tuning
The stop symbol and error code "C 000" (cancel during tuning) will be displayed by turns
with 2 s interval.
2 s interval
Error code
The one-touch tuning mode can be stopped by pushing the "SET" button regardless of
displayed item.
Stop symbol
Initial screen
Pushing the "SET" button will switch to the initial screen.
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...