5.2.6 Extension setting 3 parameters ([Pr. PF_ _ ])
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
PF21
DRT
Drive
recorder
switching
time setting
This is used to set a drive recorder switching time.
When a USB communication is cut during using a graph function or a graph function
is terminated, the function will be changed to the drive recorder function after the
setting time of this parameter.
When a value from "1" to "32767" is set, it will switch after the setting value.
When "0" is set, it will switch after 600 s.
When "-1" is set, the drive recorder function is disabled.
Setting range: -1 to 32767
0
[s]
PF23
OSCL1
Vibration
tough drive -
Oscillation
detection
level
This is used to set a filter readjustment sensitivity of [Pr. PB13 Machine resonance
suppression filter 1] and [Pr. PB15 Machine resonance suppression filter 2] while the
vibration tough drive is enabled.
Example: When you set "50" to the parameter, the filter will be readjusted at the
time of 50% or more oscillation level.
Setting range: 0 to 100
50
[%]
PF24
*OSCL2
Vibration
tough drive
function
selection
_ _ _ x Oscillation detection alarm selection
Select alarm or warning when an oscillation continues at a filter readjustment
sensitivity level of [Pr. PF23].
The digit is continuously enabled regardless of the vibration tough drive in [Pr.
PA20].
0: [AL. 54 Oscillation detection] will occur at oscillation detection.
1: [AL. F3.1 Oscillation detection warning] will occur at oscillation detection.
2: Oscillation detection function disabled
0h
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PF25
CVAT
SEMI-F47
function -
Instantaneous
power failure
detection time
(instantaneous
power failure
tough drive -
detection time)
Set the time of the [AL. 10.1 Voltage drop in the power] occurrence.
To disable the parameter, select "Disabled (_ 0 _ _)" of "SEMI-F47 function selection
(instantaneous power failure tough drive selection)" in [Pr. PA20].
When "Enabled (_ 1 _ _)" is selected of "SEMI-F47 function selection (instantaneous
power failure tough drive selection)" in [Pr. PA20], the power should be off for the
setting value of this par 1.5 s or more before cycling the power to enable a
parameter whose symbol is preceded by "*".
Setting range: 30 to 2000
200
[ms]
PF31
FRIC
Machine
diagnosis
function -
Friction
judgement
speed
Set a servo motor speed to divide a friction estimation area into high and low for the
friction estimation process of the machine diagnosis.
However, setting "0" will be the value half of the rated speed.
When your operation pattern is under rated speed, we recommend that you set half
value to the maximum speed with this.
Maximum speed in operation
[Pr. PF31] setting
Operation pattern
0 r/min
Servo motor
speed
Forward rotation
direction
Reverse rotation
direction
Setting range: 0 to
permissible speed
0
[r/min]
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...