6. NORMAL GAIN ADJUSTMENT
6 - 17
6.3.4 Response level setting in auto tuning mode
Set the response of the whole servo system by [Pr. PA09]. As the response level setting is increased, the
track ability and settling time for a command decreases, but a too high response level will generate vibration.
Hence, make setting until desired response is obtained within the vibration-free range.
If the response level setting cannot be increased up to the desired response because of machine resonance
beyond 100 Hz, filter tuning mode selection in [Pr. PB01] or machine resonance suppression filter in [Pr.
PB13] to [Pr. PB16], and [Pr. PB46] to [Pr. PB51] may be used to suppress machine resonance.
Suppressing machine resonance may allow the response level setting to increase. Refer to section 7.1.1 and
7.1.2 for settings of the adaptive tuning mode and machine resonance suppression filter.
[Pr. PA09]
Machine characteristic
Machine characteristic
Setting value
Response
Guideline for
machine resonance
frequency [Hz]
Setting value
Response
Guideline for
machine resonance
frequency [Hz]
1
Low response
2.7
21
Middle response
67.1
2
3.6
22
75.6
3
4.9
23
85.2
4
6.6
24
95.9
5
10.0
25
108.0
6
11.3
26
121.7
7
12.7
27
137.1
8
14.3
28
154.4
9
16.1
29
173.9
10
18.1
30
195.9
11
20.4
31
220.6
12
23.0
32
248.5
13
25.9
33
279.9
14
29.2
34
315.3
15
32.9
35
355.1
16
37.0
36
400.0
17
41.7
37
446.6
18
47.0
38
501.2
19
52.9
39
571.5
20
Middle response
59.6
40
High response
642.7
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...