5. PARAMETERS
5 - 26
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
Set the shape of the machine resonance suppression filter 5.
When you select "Enabled (_ _ _ 1)" of "Robust filter selection" in [Pr. PE41], the machine resonance suppression
filter 5 is not available.
PB51
NHQ5
Notch shape
selection 5
_ _ _ x Machine resonance suppression filter 5 selection
0: Disabled
1: Enabled
0h
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _ Notch width selection
0:
Į
= 2
1:
Į
= 3
2:
Į
= 4
3:
Į
= 5
0h
x _ _ _ For manufacturer setting
0h
PB52
VRF21
Vibration
suppression
control 2 -
Vibration
frequency
Set the vibration frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is "Automatic setting
(_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ 2 _)".
To enable the digit, select "3 inertia mode (_ _ _ 1)" of "Vibration suppression mode
selection" in [Pr. PA24].
Setting range: 0.1 to 300.0
100.0
[Hz]
PB53
VRF22
Vibration
suppression
control 2 -
Resonance
frequency
Set the resonance frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is "Automatic setting
(_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ 2 _)".
To enable the digit, select "3 inertia mode (_ _ _ 1)" of "Vibration suppression mode
selection" in [Pr. PA24].
Setting range: 0.1 to 300.0
100.0
[Hz]
PB54
VRF23
Vibration
suppression
control 2 -
Vibration
frequency
damping
Set a damping of the vibration frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is "Automatic setting
(_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ 2 _)".
To enable the digit, select "3 inertia mode (_ _ _ 1)" of "Vibration suppression mode
selection" in [Pr. PA24].
Setting range: 0.00 to 0.30
0.00
PB55
VRF24
Vibration
suppression
control 2 -
Resonance
frequency
damping
Set a damping of the resonance frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is "Automatic setting
(_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ 2 _)".
To enable the digit, select "3 inertia mode (_ _ _ 1)" of "Vibration suppression mode
selection" in [Pr. PA24].
Setting range: 0.00 to 0.30
0.00
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...