5. PARAMETERS
5 - 34
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
PC26
*COP5
Function
selection C-5
_ _ _ x [AL. 99 Stroke limit warning] selection
Select [AL. 99 Stroke limit warning].
0: Enabled
1: Disabled
0h
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PC30
STA2
Acceleration
time constant
2
To enable the parameter, turn on STAB2 (Speed acceleration/deceleration
selection).
This is used to set the acceleration time required to reach the rated speed from 0
r/min in response to VC (Analog speed command) and [Pr. PC05 Internal speed
command 1] to [Pr. PC11 Internal speed command 7].
Setting range: 0 to 50000
0
[ms]
PC31
STB2
Deceleration
time constant
2
To enable the parameter, turn on STAB2 (Speed acceleration/deceleration
selection).
This is used to set the deceleration time required to reach 0 r/min from the rated
speed in response to VC (Analog speed command) and [Pr. PC05 Internal speed
command 1] to [Pr. PC11 Internal speed command 7].
Setting range: 0 to 50000
0
[ms]
PC32
CMX2
Commanded
pulse
multiplication
numerator 2
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Setting range: 1 to 16777215
1
PC33
CMX3
Commanded
pulse
multiplication
numerator 3
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Setting range: 1 to 16777215
1
PC34
CMX4
Commanded
pulse
multiplication
numerator 4
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Setting range: 1 to 16777215
1
PC35
TL2
Internal
torque limit 2
Set the parameter on the assumption that the maximum torque is 100 %. The
parameter is for limiting the torque of the servo motor.
No torquet is generated when this parameter is set to "0.0".
When TL1 (Internal torque limit selection) is turned on, Internal torque limits 1 and 2
are compared and the lower value will be enabled.
Setting range: 0.0 to 100.0
100.0
[%]
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...