5. PARAMETERS
5 - 42
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
PD34
*DOP5
Function
selection D-5
_ _ _ x Alarm code output
This is used to select if output alarm codes.
Alarm codes are outputted to pins CN1-23, CN1-24, and CN1-49.
0: Disabled
1: Enabled
For details of the alarm codes, refer to chapter 8.
When you select alarm code output while MBR or ALM is selected for CN1-23, CN1-
24, or CN1-49 pin, [AL. 37 Parameter error] will occur.
0h
_ _ x _ Selection of output device at warning occurrence
Select ALM (Malfunction) output status at warning occurrence.
0h
Setting
value
Device status
0
OFF
ON
OFF
ON
WNG
ALM
Warning occurrence
1
OFF
ON
OFF
ON
WNG
ALM
Warning occurrence
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
5.2.5 Extension setting 2 parameters ([Pr. PE_ _ ])
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
PE41
EOP3
Function
selection E-3
_ _ _ x Robust filter selection
0: Disabled
1: Enabled
When you select "Enabled" of this digit, the machine resonance suppression filter 5
set in [Pr. PB51] is not available.
0h
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...