8. TROUBLESHOOTING
8 - 23
Alarm No.: 8E
Name: USB communication error
Alarm content
A communication error occurred between servo amplifier and a personal computer, etc.
Display Detail name
Cause
Check method
Check result
Action
8E.5
(1) The transmitted data
number is out of
specifications.
Check the data number
at the time of
transmission.
The transmitted data
number is out of
specifications.
Correct the transmission
data.
USB
communication
data number
error
The transmitted data
number is within
specifications.
Check (2).
(2) The communication
protocol is failure.
It is not conforming.
Modify the transmission
data according to the
communication protocol.
Check if transmission
data conforms the
communication protocol.
It is conforming.
Check (3).
(3) The setting of the
personal computer, etc.
is incorrect.
Check the setting of the
personal computer, etc.
It is incorrect.
Review the settings.
Alarm No.: 88888
Name: Watchdog
Alarm content
A part such as CPU is malfunctioning.
Display Detail name
Cause
Check method
Check result
Action
8888._ Watchdog
(1) A part in the servo
amplifier is failure.
Replace the servo
amplifier, and then check
the repeatability.
It is not repeatable.
Replace the servo
amplifier.
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...