5. PARAMETERS
5 - 17
5.2.2 Gain/filter setting parameters ([Pr. PB_ _ ])
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
PB01
FILT
Adaptive
tuning mode
(adaptive
filter II)
_ _ _ x Filter tuning mode selection
Set the adaptive filter tuning.
Select the adjustment mode of the machine resonance suppression filter 1. Refer to
section 7.1.2 for details.
0: Disabled
1: Automatic setting (Do not use this in the torque control mode.)
2: Manual setting
0h
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
_ _ _ x Vibration suppression control 1 tuning mode selection
Select the tuning mode of the vibration suppression control 1. Refer to section 7.1.5
for details.
0: Disabled
1: Automatic setting
2: Manual setting
0h
PB02
VRFT
Vibration
suppression
control tuning
mode
(advanced
vibration
suppression
control II)
_ _ x _ Vibration suppression control 2 tuning mode selection
Select the tuning mode of the vibration suppression control 2. To enable the digit,
select "3 inertia mode (_ _ _ 1)" of "Vibration suppression mode selection" in [Pr.
PA24]. Refer to section 7.1.5 for details.
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
PB03
PST
Position
command
acceleration/d
eceleration
time constant
(position
smoothing)
This is used to set the constant of a primary delay to the position command.
You can select a control method from "Primary delay" or "Linear
acceleration/deceleration" in [Pr. PB25 Function selection B-1]. The setting range of
"Linear acceleration/deceleration" is 0 ms to 10 ms. Setting of longer than 10 ms will
be recognized as 10 ms.
When the linear acceleration/deceleration is selected, do not set the "Control mode
selection" ([Pr. PA01]) to the setting other than "_ _ _ 0". Doing so will cause the
servo motor to make a sudden stop at the time of position control mode switching.
(Example) When a command is given from a synchronizing encoder, synchronous
operation will start smoothly even if it start during line operation.
Synchronizing
encoder
Start
Servo motor
Servo amplifier
ON
OFF
With time
constant setting
Without time
constant setting
Servo motor
speed
Start
t
Setting range: 0 to 65535
0
[ms]
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...