6. NORMAL GAIN ADJUSTMENT
6 - 3
6.2 One-touch tuning
You can execute the one-touch tuning with MR Configurator2 or push buttons. The following parameters are
set automatically with one-touch tuning.
Table 6.1 List of parameters automatically set with one-touch tuning
Parameter
Symbol
Name
Parameter
Symbol
Name
PA08
ATU
Auto tuning mode
PB14
NHQ1 Notch shape selection 1
PA09
RSP
Auto tuning response
PB15
NH2
Machine resonance suppression filter
2
PB16
NHQ2 Notch shape selection 2
PB01
FILT
Adaptive tuning mode (adaptive filter
II)
PB18
LPF
Low-pass filter setting
PB19
VRF11
Vibration suppression control 1 -
Vibration frequency
PB02
VRFT
Vibration suppression control tuning
mode (advanced vibration suppression
control II)
PB20
VRF12
Vibration suppression control 1 -
Resonance frequency
PB21
VRF13
Vibration suppression control 1 -
Vibration frequency damping
PB03
PST
Position command
acceleration/deceleration time
constant (position smoothing)
PB22
VRF14
Vibration suppression control 1 -
Resonance frequency damping
PB06
GD2
Load to motor inertia ratio
PB23
VFBF Low-pass filter selection
PB07
PG1
Model loop gain
PB47
NHQ3 Notch shape selection 3
PB08
PG2
Position loop gain
PB48
NH4
Machine resonance suppression filter
4
PB09
VG2
Speed loop gain
PB49
NHQ4 Notch shape selection 4
PB10
VIC
Speed integral compensation
PB51
NHQ5 Notch shape selection 5
PB12
OVA
Overshoot amount compensation
PE41
EOP3 Function selection E-3
PB13
NH1
Machine resonance suppression filter
1
6.2.1 One-touch tuning flowchart
(1) When you use MR Configurator2
Make one-touch tuning as follows.
Startup a system referring to chapter 4.
Rotate the servo motor by an external controller, etc. (The one-touch tuning cannot be performed if the
servo motor is not operating.)
Start one-touch tuning of MR Configurator2.
Select a response mode (high mode, basic mode, and low mode) in the one-touch tuning window of
MR Configurator2.
Start
Startup of the system
Operation
One-touch tuning start
Response mode selection
One-touch tuning execution
End
Push the start button to start one-touch tuning. Push it during motor driving.
When one-touch tuning is completed normally, the parameters described in table 6.1 will be set
automatically.
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...