11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 4
11.2 Regenerative option
CAUTION
Do not use servo amplifiers with regenerative options other than the combinations
specified below.
Otherwise, it may cause a fire.
11.2.1 Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
Regenerative power [W]
Servo
amplifier
Built-in
regenerative
resistor
MR-RB032
[40
ȍ
]
MR-RB12
[40
ȍ
]
MR-RB30
[13
ȍ
]
MR-RB32
[40
ȍ
]
(Note)
MR-RB50
[13
ȍ
]
MR-JE-10A
30
MR-JE-20A
30
100
MR-JE-40A
10
30
100
MR-JE-70A
20
30
100
300
MR-JE-100A
20
30
100
300
MR-JE-200A
100
300
500
MR-JE-300A
100
300
500
Note. Always install a cooling fan.
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...