4. STARTUP
4 - 22
Status display
Symbol
Unit
Description
Bus voltage
Pn
V
The voltage of main circuit converter (between P+ and N-) is displayed.
Encoder inside temperature
ETh
°C
Inside temperature of encoder detected by the encoder is displayed.
Settling time
ST
ms
Settling time is displayed. When it exceeds 1000 ms, "1000" will be displayed.
Oscillation detection
frequency
oF
Hz
Frequency at the time of oscillation detection is displayed.
Number of tough drive
operations
Td
times
The number of tough drive functions activated is displayed.
Unit power consumption 1
(increment of 1 W)
PC1
W
Unit power consumption is displayed by increment of 1 W. Positive value indicate
power running, and negative value indicate regeneration. The values in excess of
±99999 can be counted. However, the counter shows only the lower five digits of
the actual value since the servo amplifier display is five digits.
Unit power consumption 2
(increment of 1 kW)
PC2
kW
Unit power consumption is displayed by increment of 1 kW. Positive value
indicate power running, and negative value indicate regeneration.
Unit total power consumption
1 (increment of 1 Wh)
TPC1
Wh
Unit total power consumption is displayed by increment of 1 Wh. Positive value is
cumulated during power running and negative value during regeneration. The
values in excess of ±99999 can be counted. However, the counter shows only
the lower five digits of the actual value since the servo amplifier display is five
digits.
Unit total power consumption
2 (increment of 100 kWh)
TPC2 100 kWh
Unit total power consumption is displayed by increment of 100 kWh. Positive
value is cumulated during power running and negative value during regeneration.
(4) Changing the status display screen
The status display item of the servo amplifier display shown at power-on can be changed by changing
[Pr. PC36] settings. The item displayed in the initial status changes with the control mode as follows.
Control mode
Status display
Position
Cumulative feedback pulses
Position/speed
Cumulative feedback pulses/servo motor speed
Speed
Servo motor speed
Speed/torque
Servo motor speed/analog torque command voltage
Torque
Analog torque command voltage
Torque/position
Analog torque command voltage/cumulative feedback
pulses
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...