4. STARTUP
4 - 27
(2) Operation example
(a) Parameters of 5 or less digits
The following example shows the operation procedure performed after power-on to change the
control mode to the speed control mode with [Pr. PA01 Operation mode]. Press "MODE" to switch to
the basic setting parameter screen.
The parameter number is displayed.
Press "UP" or "DOWN" to change the number.
The set value of the specified parameter number flickers.
Press "SET" twice.
Press "SET" to enter.
Press "UP" twice.
During flickering, the set value can be changed.
Use "UP" or "DOWN".
(_ _ _ 2: Speed control mode)
……
……
……
To shift to the next parameter, press the "UP" or "DOWN" button.
When changing the [Pr. PA01] setting, change its set value, then switch power off once and switch it
on again to enable the new value.
(b) Parameters of 6 or more digits
The following example gives the operation procedure to change the electronic gear numerator to
"123456" with [Pr. PA06 Electronic gear numerator].
The screen flickers.
Press "MODE" to switch to the basic setting parameter screen.
Press "UP" or "DOWN" to select [Pr. PA06].
Press "SET" once.
Press "SET" once.
Setting of upper 1 digit
Press "UP" or "DOWN" to
change the setting.
Press "SET" once.
Enter the setting.
Press "MODE" once.
Press "MODE" once.
Setting of lower 4 digits
……
……
……
…
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...