5. PARAMETERS
5 - 21
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
PB18
LPF
Low-pass
filter setting
Set the low-pass filter.
The following shows a relation of a required parameter to this parameter.
Setting range: 100 to 18000
3141
[rad/s]
[Pr. PB23]
[Pr. PB18]
_ _ 0 _ (Initial value)
Automatic setting
_ _ 1 _
Setting value
enabled
_ _ 2 _
Setting value
disabled
PB19
VRF11
Vibration
suppression
control 1 -
Vibration
frequency
Set the vibration frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting
(_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ _ 2)". Refer to section 7.1.5 for details.
Setting range: 0.1 to 300.0
100.0
[Hz]
PB20
VRF12
Vibration
suppression
control 1 -
Resonance
frequency
Set the resonance frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting
(_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ _ 2)". Refer to section 7.1.5 for details.
Setting range: 0.1 to 300.0
100.0
[Hz]
PB21
VRF13
Vibration
suppression
control 1 -
Vibration
frequency
damping
Set a damping of the vibration frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting
(_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ _ 2)". Refer to section 7.1.5 for details.
Setting range: 0.00 to 0.30
0.00
PB22
VRF14
Vibration
suppression
control 1 -
Resonance
frequency
damping
Set a damping of the resonance frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting
(_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ _ 2)". Refer to section 7.1.5 for details.
Setting range: 0.00 to 0.30
0.00
PB23
VFBF
Low-pass
filter selection
_ _ _ x Shaft resonance suppression filter selection
Select the shaft resonance suppression filter.
0: Automatic setting
1: Manual setting
2: Disabled
When you select "Enabled (_ _ _ 1)" of "Machine resonance suppression filter 4
selection" in [Pr. PB49], the shaft resonance suppression filter is not available.
0h
_ _ x _ Low-pass filter selection
Select the low-pass filter.
0: Automatic setting
1: Manual setting
2: Disabled
0h
_ x _ _ For manufacturer setting
1h
x _ _ _
0h
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...