8. TROUBLESHOOTING
8 - 3
Alarm code
Alarm deactivation
No.
CN1
49
(Bit 2)
CN1
23
(Bit 1)
CN1
24
(Bit 0)
Name
Detailed
display
Detail name
Stop
method
(Note 2,
3)
Alarm
reset
(RES)
Press
the
"SET"
button
on the
current
alarm
screen.
Power
off to
On
(Note 4)
24.1
Ground fault detected by hardware
detection circuit
DB
Alarm
24
1
0
0
Main circuit error
24.2
Ground fault detected by software
detection function
DB
30.1
Regeneration heat error
DB
(Note 1)
(Note 1)
(Note 1)
30
0
0
1
Regenerative error
(Note 1)
30.2
Regeneration signal error
DB
(Note 1)
(Note 1)
(Note 1)
30.3
Regeneration feedback signal error
DB
(Note 1)
(Note 1)
(Note 1)
31
1
0
1
Overspeed
31.1
Abnormal motor speed
SD
32.1
Overcurrent detected at hardware
detection circuit (during operation)
DB
32.2
Overcurrent detected at software detection
function (during operation)
DB
32
1
0
0
Overcurrent
32.3
Overcurrent detected at hardware
detection circuit (during a stop)
DB
32.4
Overcurrent detected at software detection
function (during a stop)
DB
33
0
0
1
Overvoltage
33.1
Main circuit voltage error
DB
35
1
0
1
Command frequency error
35.1
Command frequency error
SD
37.1
Parameter setting range error
DB
37
0
0
0
Parameter error
37.2
Parameter combination error
DB
45
0
1
1
Main circuit device
overheat (Note 1)
45.1
Main circuit device overheat error
SD
(Note 1)
(Note 1)
(Note 1)
46.1
Abnormal temperature of servo motor 1
SD
(Note 1)
(Note 1)
(Note 1)
46
0
1
1
Servo motor overheat
(Note 1)
46.5
Abnormal temperature of servo motor 3
DB
(Note 1)
(Note 1)
(Note 1)
46.6
Abnormal temperature of servo motor 4
DB
(Note 1)
(Note 1)
(Note 1)
47
0
1
1
Cooling fan error
47.2
Cooling fan speed reduction error
SD
50.1
Thermal overload error 1 during operation
SD
(Note 1)
(Note 1)
(Note 1)
50.2
Thermal overload error 2 during operation
SD
(Note 1)
(Note 1)
(Note 1)
50.3
Thermal overload error 4 during operation
SD
(Note 1)
(Note 1)
(Note 1)
50
0
1
1
Overload 1 (Note 1)
50.4
Thermal overload error 1 during a stop
SD
(Note 1)
(Note 1)
(Note 1)
50.5
Thermal overload error 2 during a stop
SD
(Note 1)
(Note 1)
(Note 1)
50.6
Thermal overload error 4 during a stop
SD
(Note 1)
(Note 1)
(Note 1)
51.1
Thermal overload error 3 during operation
DB
(Note 1)
(Note 1)
(Note 1)
51
0
1
1
Overload 2 (Note 1)
51.2
Thermal overload error 3 during a stop
DB
(Note 1)
(Note 1)
(Note 1)
52.1
Excess droop pulse 1
SD
52.3
Excess droop pulse 2
SD
52
1
0
1
Error excessive
52.4
Error excessive during 0 torque limit
SD
52.5
Excess droop pulse 3
DB
54
0
1
1
Oscillation detection
54.1
Oscillation detection error
DB
56.2
Over speed during forced stop
DB
56
1
1
0
Forced stop error
56.3
Estimated distance over during forced stop
DB
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...