10. CHARACTERISTICS
10 - 2
Operation time [s]
1000
100
10
1
0.1
100
200
300
0
Servo-lock
Operating
50
150
250
(Note) Load ratio [%]
320
1000
100
10
1
0.1
100
200
300
0
50
150
250
320
Operation time [s]
Servo-lock
Operating
(Note) Load ratio [%]
HF-KN13, HF-KN23, HF-KN43
HF-KN73, HF-SN52, HF-SN102
HF-SN152, HF-SN202, HF-SN302
Note. If operation that generates torque more than 100% of the rating is performed with an abnormally high frequency in a servo motor
stop status (servo-lock status) or in a 30 r/min or less low-speed operation status, the servo amplifier may malfunction regardless
of the electronic thermal protection.
Fig. 10.1 Electronic thermal protection characteristics