Evacuate and charge system according to previously described
procedure.
Adjust fresh air control cable, refer to HEATER CONTROL LE-
VER ASSEMBLY in HEATER AND VENTILATION section.
Install the cutting part of drain hose (1) downward as shown in
figure.
INSPECTION
Check the following
Evaporator fins for leakage, blockage and damage.
Evaporator fittings for leakage.
Clogged evaporator fins should be washed with water, and should
be dried with compressed air.
NOTE:
Be careful not to damage evaporator fins. If evaporator fin
is bent, straighten it by using a screwdriver or pair of pliers,
If any leakage is found from fitting or tube, repair or replace
evaporator.
When the thermistor removed, its should be reinstalled in
original position.
A/C EVAPORATOR THERMISTOR
Check resistance between evaporator thermistor (1) terminals.
If check results are as not specified, replace thermistor.
NOTE:
When the thermistor removed, its should be reinstalled in
original position.
1B-20
AIR CONDITIONING (OPTIONAL)
Sensor Temperature (
C (
F))
Resistance (k
)
0 (32)
4.6 – 5.1
15 (59)
2.1 – 2.6