BLOWER FAN MOTOR RESISTOR
REMOVAL
1) Disconnect negative (–) cable at battery.
2) Disconnect resistor coupler (1).
3) Remove blower motor resistor (2) by removing its mounting
screw (3).
INSPECTION
Measure each terminal-to-terminal resistance on resistor
Resistance
Me – Lo: 1.5 – 3.0
at 25
C (77
F)
Me – Hi : 0.5 – 1.5
at 25
C (77
F)
If measured resistance is incorrect, replace blower motor resistor.
INSTALLATION
Reverse removal procedure for installation.
1A-8
HEATER AND VENTILATION