6H-22
CHARGING SYSTEM
SPECIFICATIONS
BATTERY
Rated capacity
28 AH / 5 HR, 12 Volts
Electrolyte
2.5 L (5.28 / 4.40 US / lmp pt)
Electrolyte S.G.
1.24 when fully charged at 20
C (68
F)
GENERATOR
NOTE:
The generator used in each vehicle is one of the following two types, depending on specification.
Type
40 A type
50 A type
Rated voltage
12 V
Nominal output
40 A (at 13.5 V)
50 A (at 13.5 V)
Permissible max. speed
18,000 rpm
No-load speed
1,110 r/min (rpm)
Setting voltage
14.2 to 14.8 V
Permissible ambient temperature
–30 to 90
C (–22 to 194
F)
Polarity
Negative ground
Rotation
Clockwise viewed from pulley side