Chapter 1 Built-in FEnet communication
1-83
Buil
t-
in
Comm
Buil
t-
in
2) Direct and remote 2-stage access in the PC connected Ethernet
It is possible to realize the remote 2-stage access through Ethernet. The method is the same as the
remote 1-stage and the example of setting access options is as below.
[Fig. 1.9.3] Direct and remote 2-stage access in the PC
Notice
Instructions for remote 1-stage/2-stage access
(1) In case the currently open project in XG5000 is not matched with the accessed 1-stage and 2-stage
CPU types, the following menu items are not available.
a) Write program and each parameter
b) Read program and each parameter
c) Monitor
d) Link Enable setting
e) I/O information
f) Forced I/O information
(2) Open the project to be accessed and execute remote access when programming XG5000
을
through remote 1-stage and 2-stage access.
(3) The remote access is supported up to 2-stage only and further remote access is not allowable.
(4) In case of writing parameters after modifying communication parameters through remote access,
the modified parameters will be applied only after disconnecting remote access.
Summary of Contents for XBE-DC08A
Page 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Page 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Page 644: ...Positioning Chapter 8 Functions 8 91 ...
Page 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Page 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Page 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...