P
o
sit
io
n
in
g
Chapter 7 Program
7-20
(4) Ellipse Interpolation
(a) This is the condition for Ellipse Interpolation
This is the condition for Ellipse Interpolation Command (XELIN)
(b) Operating state by axis
According to exercise from “Chapter 7.1.2 Current State Reading,” it is a signal of “Operating” for each axis. It turns on
when it is operating. Operating Data Setting can not be configured while it is running hence configuration will only be
configured when it is not running. If you execute Ellipse Interpolation while it is running, the “error 541” would be
appeared.
(c) Error state for each axis
According to exercise from “Chapter 7.1.2 Current State Reading,” it is a signal of “Error state” for each axis. It turns on
when an error occurred. Operation will only work when there is no error. If you want to operate a system regardless of
errors, you can just inactivate the function.
(d) Ready signal for each axis
According to exercise from “Chapter 7.1.2 Current State Reading,” it is a signal of “Drive Ready” for each axis. This
command only works when this is the condition for Drive Ready is on. If a Drive Ready of main axis is not set as “ON,”
the “error 549” would be appeared and If a Drive Ready of subordinate axis is not set as “ON,” the “error 550” would
be appeared and
(e) Address of Positioning Module
In this example, Positioning Module is fixed at the 1 slot of 0 bases.
(f) Axis of command execution
You can set an axis for Parameter Setting. UP type supports for 4 axes. In the “execution of axis” from the
configuration of Parameter Setting, you can set a value for axis1 through axis4.
(g) Operating step number by Ellipse Interpolation
Set the operating step number by Ellipse Interpolation. The setting of main operating step and subordinate step is the
same.
(h) Ratio of Ellipse Interpolation Axis
Set both ratio values for main and subordinate axis of set operates data from circular interpolation locus. It is to change
circular locus into ellipse locus by using ratio of main and subordinate axis.
(i) Angle of Ellipse Interpolating Operation
Set the degree for Ellipse Interpolating Operation. Unit is [X10
-1
degree]. For more information, reference for Ellipse
Interpolation is in the “Chapter 8.2.13”
(j) State of Operation complete
Summary of Contents for XBE-DC08A
Page 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Page 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Page 644: ...Positioning Chapter 8 Functions 8 91 ...
Page 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Page 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Page 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...