[ Example ]
- When indirect start command is executed[when Step No. of command is set to 0].
- Starting command execute total four times.
■ Setting of XG-PM
Step NO.
Control Method
Operation
Method
Goal Position
[pls]
Operation
Speed [pls/s]
Accel NO.
Decel
NO.
M Code
Dwell Time
1
Absolute Single-axis
Positioning Control
Single,End
10000
1000
1
1
0
0
2
Absolute Single-axis
Positioning Control
Single,End
15000
500
1
1
0
0
3
Absolute Single-axis
Positioning Control
Single,End
25000
1000
1
1
0
0
4
Absolute Single-axis
Positioning Control
Single,End
30000
500
1
1
0
0
■ Operation Pattern
Speed
Time
ON
Start
command
In
operation
ON
ON
ON
ON
ON
ON
ON
step nor : 1
step nor : 2
step nor : 3
step nor : 4
Operation mode :
Singularp End
Operation mode :
Singularp End
Operation mode :
Singularp End
Operation mode :
Singularp End
1ttt
5tt
The operating step for each starting command will be
[1] → [2] → [3] → [4].
Summary of Contents for XBE-DC08A
Page 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Page 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Page 644: ...Positioning Chapter 8 Functions 8 91 ...
Page 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Page 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Page 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...