Po
sit
io
n
in
g
Chapter 7 Program
7-3
occurred, “0” will be outputted.
(f) Error State
This is the area that output error no. if there are errors in operation of function block.
(3) Encoder value Reading
(a) Module’s ready
After Turn On, if there is no error occurred in Positioning Module, it is “ON,” meaning that modules are ready to operate.
(b) Address of Positioning Module
In this example, Positioning Module is fixed at the 1 slot of 0 bases.
(c) Encoder No.
Set the encoder no. to read encoder value. UP type must be set as 0.
(d) Encoder value
The current value of encoder is displayed.
(e) State of Operation complete
If function block is completed without error, “1” will be outputted and maintain “1” until the next operation. If error
occurred, “0” will be outputted.
(f) Error State
This is the area that output error no. if there are errors in operation of function block.
Summary of Contents for XBE-DC08A
Page 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Page 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Page 644: ...Positioning Chapter 8 Functions 8 91 ...
Page 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Page 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Page 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...